Electrical Characteristics
Power supply 10V ~ 40VDC, capacity 0.03KVA
Peak output current 3A / phase (Max) (current can be panel DIP switch setting)
Drive constant phase flow PWM control
Excitation mode full step, half step, four segments, eight segments, 16 segments, 32 segments, 64 segments, 128 segments
Insulation resistance at room temperature and atmospheric pressure> 100MΩ
Dielectric strength at room temperature and atmospheric pressure 0.5KV, 1Min
Environment and parameters
Cooling Natural cooling (under adverse circumstances require additional auxiliary heat)
Avoid the use of environment where dust, oil mist and corrosive gases
Temperature -5 ℃ ~ + 40 ℃
Humidity <80% RH, non-condensing, no frost
Vibration 5.9m / s2Max
Storage temperature -40 ℃ ~ + 55 ℃
Humidity <93% RH, non-condensing, no frost
Dimensions 116 × 60 × 37mm
Weight 0.21 Kg
[Note] prompted dramatic changes in storage due to ambient temperature, prone to condensation or frost, you should place the drive more than 12 hours until the drive temperature and the ambient temperature in a consistent run before electricity.
Supply Voltage
Drive internal switching power supply design ensures that you can adapt to a wide voltage range, the user can choose according to their own situation between 10V to 40VDC. Generally the higher rated supply voltage help to improve high-speed torque motor, but it will increase the drive's loss and temperature rise.
Output current selection
The maximum output current drive is 3A / phase (peak), the drive panel by six DIP switches can be combined in the first three out of eight 5,6,7 state, corresponding to eight output current from 0.9A to 3A to cater for different motors.
Select subdivision
The driver can provide full step, half-step improvement, four segments, eight segments, 16 segments, 32 segments, 64 segments and 128 segments of eight operating modes, using the drive panel DIP switches of the first six 1,2,3 three different states can be combined (see breakdown mode selection table). Description: white box panel screen printing on the actual location of the corresponding switch.
Semi-automatic current
If the host controller did not issue a pulse signal within half a second, the drive will automatically enter power-saving semi-current operating mode, the phase current motor winding will be reduced to half of the set value, in this state, the motor and drive power consumption can be reduced, but the motor output torque is also correspondingly reduced. When the arrival of the next pulse drive output current rating of automatic recovery.
Wrong phase protection
When the two-phase motor and drive is connected, the user can easily pick the wrong phase, which seriously damage the drive. The driver of the wrong phase protection circuit design. Even if the user pick the wrong phase, the drive will not be damaged, but the motor will not run properly, mainly in output is minimal. If this happens, you should check the motor wiring is correct.
About the heat
Operating temperature is too high is the source of most of the line failures, effective cooling is particularly important for improving the reliability and operating life. Recommended to drive tightly fixed on the user's metal chassis, cooling assistance through the chassis backplane. Able to do so also in contact with the surface of a thermally conductive material, such as adding grease. If additional cooling fan, the temperature rise of the drive will be greatly reduced.