First, maintenance and precautions
(1) The equipment shall be specifically responsible for operation and maintenance, maintenance personnel should have appropriate knowledge of electrical and computer, the operator should have a good sense of responsibility. Other personnel to operate the equipment is strictly prohibited.
(2) If the power grid fluctuations, it is recommended that purchase of power supply. Optional AC voltage regulator, also choose UPS uninterruptible power supply. If AC power supply, we must first ensure that the quality of power supply, AC power supply should always check the stability of voltage and stability, absolutely prevent the input voltage is too high.
(3) strictly in accordance with guidelines specified in the steps.
(4) Print Needle from the print surface is not too low, should be kept 3 ~ 10mm, otherwise it will damage the print pin. Operation of equipment should endeavor to follow a principle of engraving, low step by step. Marking the beginning not to object does not matter, you can gradually reduce the height until it reaches the appropriate height appropriate to the depth of the engraving effect, start engraving objects too close to the needle tip is not only easy to damage, but also easy to scratch engraving the object itself. When you find a suitable height, we can refer to later engraving engraved highly similar objects can refer to a high degree of implementation of this engraving. (Engraving depth and pressure and needle distance, the appropriate adjustment to achieve the best results)
(5) Do not move equipment or devices. To move, do not pull a bad connection.
(6) try not to use the computer in the engraving control over other software, to prevent the virus.
(7) should be used regularly for three to five months in the rally marking machine lubricating linear motion guide (do not use fats and oils of lubricating oil, try using the lubricating liquids, mainly played the role of cleaning guide auxiliary lubrication, fats and oils run too much oil may affect marking accuracy), but the needle comprising the O-ring to avoid tainted oil, otherwise the needle may be out of the pin set is not caused by outside outlet. Therefore, oil can not point out the needle.
(8) found to have irregularities should be immediately stopped, and repair. Maintenance and supply units should be contacted.
(9) equipment before first use, or try to do a boot from the new nose reset. (See software tutorials on how reset) device does not use or turned off the machine, due to human impact or uneven ground will result in some displacement of the needle. (Equipment in a situation of no electricity can move the needle is, please note that if found to have stamped location is not accurate head when you think have not done any reset) nose reset the device from the new goal is to return to zero far point, to accurately marking the location.
Second, common problems and solutions:
1. Almost all the issues or the reasons behind the failure may be very simple, might check yourself, to solve.
2. First comprehensive inspection of the entire system, all cables are solid and reliable. Power supply, gas supply and switch and instructions are normal.
3. Electrical work license holder must disconnect all power cords in staff, in the beginning to ensure the safety of the operation! ! !